General Programme 2024

EN ISO 20345:2022 - EN ISO 20347:2022 BASIC REQUIREMENTS + ADDITIONAL REQUIREMENTS FOR FOOTWEAR FOOTWEAR CLASSIFICATION - Class I : Footwear made from leather and other materials, excluding all-rubber and all-polymeric footwear. - Class II footwear : All-rubber footwear (i.e. entirely vulcanised) or all-polymeric (i.e. entirely moulded).

BASIC REQUIREMENTS - Whole footwear : height of upper; heel area; constructional performance of outsole (construction and upper/outsole bond strength); toe protection and toe cap properties (except for footwear under EN ISO 20347), slip resistance. - Upper : properties of materials of upper, lining, tongue, insole/insock (tear strength, abrasion resistance, tensile properties, water vapour permeability, pH, insole/footbed absorption and deabsorption). - Outsole : construction and tear strength, abrasion resistance, flexing resistance, resistance to hydrolysis, interlayer bond strength and resistance to hydrocarbon oils

M INIMUM RE Q UIRED VALUES

PROTECTION CLASS

EN ISO 20345:2022

EN ISO 20347:2022

SB S1 S2 S3 S3L S3 S S6 S7 S7L S7 S OB O1 O2 O3 O3L O3 S

I o II I

I

I

I

I

I

I

I

I

I o II

I

I

I

I

I

C l ass

O X X X X X X X X X O X X X X X

Closed seat regio n

Toe ca p resistant to an im p act o f 2 00 Jou l es

X X X X X X X X X X -

-

-

-

-

-

O O O X X X O X X X O O O X X X

C leated outsole

Perforation resistanc e ( metallic insert P ) *

P

O O O X -

- O X -

-

O O O X -

-

Per f oration f orce ≥ 1100N

P e r fo r a ti o n r es i s t a n ce ( non-metallic insert, test with nail, Ø 4.5 mm ) Per f oration resistanc e ( non-metallic insert, test with nail, Ø 3.0 mm)

PL

O O O - X - O - X -

O O O -

X -

PS

O O O - -

X O - -

X O O O -

-

X

El ec tri ca l r es i s t a n ce > 1 00 kΩ ≤ 1 000 kΩ

O X X X X X X X X X O X X X X X

A

A nti s t a ti c f oo tw ear

Temperature increase ≤ 22 ° C when placed on a plate at a temperature o f 150 ° C for 30’ Temperature decrease ≤ 10 ° C in an environment at -17 ° C for 30 ’

O O O O O O O O O O O O O O O O

HI

Heat insulation o f insole comple x

CI

O O O O O O O O O O O O O O O O

C old insulation of insole com p lex

E

O X X X X X X X X X O X X X X X

Ener g y absorption in heel are a

> 2 0 Jou l es

WR

O O O O O O X X X X O O O O O O

Water resistanc e

No water penetration

No hole throu g hout thickness a f ter 8,000 cyc l es

O

S C

O O O O O O O O

O O O O O O O

A brasion resistance o f scu ff ca p

S lip resistance on ceramic floor wi t h g l ycer i n

S R

X X X X X X X X X X X X X X X X

Test on ceramic fl oor with g lycerin.

W PA Water p enetration and absor p tio n

O O X X X X - - -

-

O O X X X X

H2O absor p tion after 60’ ≤ 30%

Co nt ac t a t 300 ° C f o r 60 ’’ - D oes not me l t

HR O R es i stance to h ot contact

O O O O O O O O O O O O O O O O

F O

O O O O O O O O O O O O O O O O

Resistance to h y drocarbons

Volume increase o f sole sam p le < 12 %

L G

O O O O O O O O O O O O O O O O

L a dd er gr i p

W idth o f central outsole area > 35 mm

X O –

M andator y requirement for protection class Optional requ i rement a dd e d to man d atory ones , if marked on marking N o t man d ator y requirement, check f ootwear stamping

Partially conductive footwear Partially conductive footwear should be used if it is necessary to minimize electrostatic charges in the shortest possible time, e.g. when handling explosives. Electrically conductive footwear should not be used if the risk of shock from any electrical apparatus or live parts with alternating or direct voltage has not been completely eliminated. In order to ensure that this footwear is partially conductive, it has been specified to have an upper limit of resistance of 100 kΩ in its new state Antistatic footwear Antistatic footwear must be used when there is the need to minimize the accumulation of electrostatic charges, so as to rule out the danger of combustion of flammable substances and vapours and in case the risk of electric shocks from live parts should persist. Antistatic footwear does not provide protection against electric shock, as it only creates an electrical resistance between the floor and the foot. If the danger of electric shock cannot be completely ruled out, additional precautions must be taken as part of a periodic plan for accident prevention in the workplace. For antistatic requirements to be met, the footwear must not be modified.

NB The certificates of the footwear certified in accordance with old standards will be effective until the expiration thereof.

627 